Design Standard | BS EN 13355:2004+A1:2009 BS EN 60204:2006+A1:2009 |
BOOTH DIMENSIONS | |
Internal dimensions | 6900×4000×2800mm (L×W×H) |
External dimensions | 10670×4110×2800mm(L×W×H) |
Basement | |
Base design | Galvanized sheet bending forming, full grids Basement(H): 350mm |
Carrying capacity of the grids | 650kg /wheel |
Filter area | 27.6 m2 |
Drive-in-ramp | 2 pieces; size:2000*520mm,diamond structure |
Grid description | Size: 997 X 756mm, 40 X 3mm, galvanized pressed steel grates instead of conventional steel grates with twisted bars. Aesthetics, durability, stress resistance are the most important features of pressed steel grates. |
Filtration System | |
Pre-filter | Fiberglass paint plate filters |
Exhaust filter | Fiberglass paint arrestor filters, with features of big ventilation volume, small resistance and flame resistance, etc. |
Exhaust System | |
Exhaust fan | Direct-type turbine fan |
Power and motor description | 1×7.5KW,970RPM,380V,50HZ;CE |
Parameter of exhaust fan | 28,000 m3/h ;650pa |
Ductwork | Straight ducting:4 pieces ; 90° :1 piece ; Reducer: 1 piece |
Control System | |
Implementation standards | Standard Y/Δ step-down start control system |
Features | Fan start,emergency stop switch, failure indication |