Hangzhou Mig Packaging Co., Ltd. / 2022-06-23
=== Base Info ===
=== Description ===
ITEMS | SPECIFICATIONS |
Model | IT-SUPER-L10 Direct Gas Fired Heating Spray Booth |
Design standard | BS EN 13355: 2004+A1:2009 BS EN 60204: 2006+A1:2009 |
Internal dimensions | 10000 X 4000 X 3000mm (L X W X H) |
External dimensions | 10110 X 5760 X 4010mm (L X W X H) |
Airflow | Full downdraft |
Plenum (height) | 600mm |
Extraction | Through 350mm raised metal basement |
Extraction area | 40m2 |
Grids carrying capacity | 900kg/wheel |
Entrance door | 3400x3250mm (WxH), 1 set |
Service door | 800x2000mm(WxH), 2 sets |
Walls | 50mm rock wool walls |
Ceiling lights (LED) | 14 sets, each 6 X 18W, 1,512W total |
Sidewall lights (LED) | 12 sets, each 2 X 18W, 432W total |
Brightness | >1,500LUX |
Filters | Bag filter, high efficiency ceiling filter, floor filter, exhaust filter |
Intake/Exhaust unit | Direct-type turbine fan, 2x11KW, CE motor |
Air volume | 35,000m3/h |
Empty loaded air speed | 0.24m/s |
Heats | Direct gas fired heating system, 410kw direct fired burner |
Calorific value | 400,000kcal/h |
Maximum working temperature | 80ºC |
Controls | CE standard control box |
Inverter | SCHNEIDER inverter |
Stack light | Yes |
Voltage | 380V, 50Hz, 3ph |
Rated power | 30KW |
Item | Specification |
Pre-filter | Bag filter |
Ceiling filter | High efficiency F5 grade filter |
Floor filter | Fiberglass paint stop filter |
Extract filter | Activated carbon filter |