Factory Direct Corrugated Sidewall Conveyor Belt China
Homedia (Zhangzhou) Import and Export Co., Ltd. / 2022-06-27
- Type:PVC Pvg Belt
- Material:Rubber
- Inside Material:Whole Core
- Feature:Oil-Resistant, Acid And Alkali Resistant, Tear-Resistant, Heat-Resistant, Cold-Resistant, Wear-Resistant, Fire Resistant
- Tensile Strength:Strong
- Width:500-1600mm
=== Base Info ===
- Model NO.:sidewall conveyor belt
- Material Feature:Flame Retardant
- Usage:Transmission Chain, Transportation Chain, Dedica
- Color:Black
- Standard:GB,DIN,En ISO,Sans1366,A1333
- Transport Package:Water-Proof and UV-Proof Cloth All Side
- Specification:680s-2500s
- Trademark:HYRUBBERS
- Origin:Shandong
- HS Code:401012
- Production Capacity:1000m,Day
=== Description ===
Type and technical parameter of PVC conveyer belt: |
Standard MT914-2008 | Safety factor 10(Breaking strength*1/10) |
The Slope <16ºC |
Standard type | Degree | Breaking strength≥,N/mm | Tensile yield≥,% | Advising Mindiameter of Transmission Drum |
Longitudinal | Transverse | Longitudinal | Transverse |
680S | 4th | 680 | 265 | 15 | 18 | 320 |
800S | 5th | 800 | 280 | 400 |
1000S | 6th | 1000 | 300 | 500 |
1250S | 7th | 1250 | 350 | 500 |
1400S | 8th | 1400 | 350 | 630 |
1600S | 8th | 1600 | 400 | |
750 |
|
Type and technical parameter of PVG conveyer belt: |
Standard MT914-2008 BS3289 HG2805 | Safety factor 10(Breaking strength*1/10) |
Standard type | Degree | The slope <20ºC | Recommend minimum roller diameter |
Breaking strength≥,N/mm | Tensile yield≥,% |
Longitudinal | Transverse | Longitudinal | Transverse |
680S | 4th | 680 | 265 | 15 | 18 | 400 |
800S | 5th | 800 | 280 | 500 |
1000S | 6th | 1000 | 300 | 630 |
1250S | 7th | 1250 | 350 | 750 |
1400S | 8th | 1400 | 350 | 750 |
1600s | 9th | 1600 | 400 | |
750 |
|
Safe function:
Function Name | The alcohol combustion | The propane combustion | Electrical conductivity | The roller rub |
Standard value | Average value≤3S,List value≤10S(Have no cover gum) | a)≥600 | ≤3X108Ω | ≤325ºC |
Average value≤5S,List value≤15S(Have no cover gum) | b)≥50mm;≤140ºC≤1250mm | |