High Quality The Disposable Collection Swab/Throat Swab

Dongguan Xiechuang Enterprise Co., Ltd. / 2022-06-23

High Quality The Disposable Collection Swab/Throat Swab

  • Type:Test Strips & Test Tube
  • Material:Plastic
  • Ethylene Oxide Sterilization:Without Ethylene Oxide Sterilization
  • Quality Guarantee Period:Two Years
  • Group:Adult
  • Logo Printing:With Logo Printing

=== Base Info ===

  • Model NO.:DS-A
  • Transport Package:1piece, Bag, 100pieces , Bag, 200pieces , Bag, 500
  • Specification:21mm× 80mm
  • Trademark:JSHXRT
  • Origin:Taizhou
  • HS Code:3212963240
  • Production Capacity:1, 00000 Piece , Day

=== Description ===
Model No.DS-AMaterial  Rubber PlasticCertificateCEUsageLab,HospTrademarkJSHXRTSpecification1piece/ bagOriginTaizhou  
High Quality The Disposable Collection Swab/Throat Swab

 

Product NameDisposable Sampler
Model/TypeA: 1piece/ bag, 100pieces / bag, 200pieces / bag, 500pieces / bag.
B: 1piece / bag, 100pieces / bag, 200pieces / bag, 500 pieces/ bag.
Intended UseDisposable Sampler is intended is used for collection, transportation and storage of samples(viruses, chlamydiae, mycoplasma and ureaplasma).
IndicationUsed for collection, storage and transportation of viruses, chlamydiae, mycoplasma and ureaplasma.
Contraindication
 
The product is strictly prohibited for the sampling of bacterial samples, and the preservative liquid itself contains antibiotics which inhibit the bacteria.
Test populationApplicable for all population necessary for swabbing
Intended usersQualified doctors, nurses for specimen collection in a medical laboratory or hospital
ComponentIt is usually composed of swabs.
Scope of applicationIt is used for collection, transportation and storage of samples.
Precautions/cautions
  1. This product is for single use only. It must be strictly implemented according to the instruction for use
  2. It should be destroyed immediately after use. 
  3. It is forbidden to reuse. 
  4. The disposal of its wastes should be carried out according to the relevant laws and regulations of the state on environmental protection.
  5. Products should be stored in dry, ventilated, radiant, clean rooms.
  6. The batch number of the product is at the seal of the packing, and it is valid for 2 years.
  7. Please read the instruction manual carefully and pay attention to the date of production and batch number before use.
Warning
 
  1. This product is a disposable product, so it is forbidden to reuse. After use, it should be treated as medical waste;  
  2. Before use, please pay attention to whether the packaging and products are damaged or have other obvious defects. Please check whether the product is within the validity period. If it is beyond the validity period, please do not use it.  
3. Please read the relevant instructions carefully before use, and be familiar with the instructions and operation methods of the product.  
Instruction for use1.Sterilization of the sampling tube and swab can be done before the medical institution or the user is used.
2.Annotate the relevant sample information on the sampling tube and inject an appropriate amount of sample solution.
3.According to different sampling requirements, sample swabs were sampled at the corresponding locations, holding the handle gently inserting the swab into the sampling area, gently rotating the swab 3-5 times, and then slowly removing it.
4.The sample is put into the sampling tube, and the sample swab is broken out of the sampling tube, then the tube cover is tightened, and the sample is sealed to complete the sampling.
5.The newly collected clinical specimens should be transported to the laboratory within 48 hours at 4ºC, and can not be sent to the laboratory for 48 hours. They should be kept at -70ºC or below. Specimens sent to the laboratory should be inoculated and separated as soon as possible, and can be stored at 4ºCfor 48 hours. If the inoculum is not inoculated, it should be kept at -70 ºC or below.
6.The conventional sampling methods are as follows:
A) nasal swab: gently wipe the swab head into the nasal passages of the nasal passages, and then slowly exit after stopping for a moment. Wipe the other nostrils with another swab, immerse the swab head in the sample, and discard the tail.
B) pharyngeal swabs: wipe the bilateral pharyngeal tonsils and the posterior pharyngeal wall with swabs, immerse the swab head in the sampling fluid, and discard the tail.
C) gargle: gargle with 10mL normal saline, rinse the head back, make the "Oh" sound, let the saline rotate in the pharynx, and collect the lotion with the 50mL empty sampling tube.
D) nasal lotion: the patient took his posture and his head was slightly backward, injecting 50mL normal saline into the nostril by pipette. He told the patient to simultaneously send K tone to close the pharyngeal cavity, then let the patient lower his head and let out the normal saline, collect the lotion with 50mL empty sampling tube, and repeat the process to wash the two nostrils.
E) nasopharyngeal aspirates: tracheal and bronchial secretions are often collected by this method. Mucus is extracted from the nasopharynx with a collector connected to a negative pressure pump. First, the collector head is inserted into the nasal cavity, and the negative pressure is turned on. The head of the collector is collected and slowly pushed out. Collecting mucus and washing the collector with liquid 5mL for three times.
F) autopsy specimens: autopsy tissue specimens were collected and samples were separated when necessary. Specimens were autopsy tissue.
G) samples of mycoplasma, chlamydia and Ureaplasma samples: male: use sterile cotton swabs to rotate around the urethra about
2cm for a few seconds. Female: remove the mucus from the cervical mucus and insert the 1-2cm into the cervical canal with sterile swab.

 
Shelf Life
 
2 years
Duration
 
single-use only
Storage condition
 
Store at ambient temperature and store in dry and ventilated places. Be careful of damp. Do not store with poisonous or special smell. Avoid direct contact with fire sources and inflammable and corrosive substances.
 Company:Jiangsu Huaxia Ruitai Plastic Industry Co. Ltd.
Address:Modem technology industry Zone, Jiangyan District,Taizhou, City. 
 
 
 Company: Wellkang Ltd 
Address: 16 Castle Street, Dover, CT16 1PW, England, UK
  
   
   






 

Copyright 2024 357th.com All Rights Reserved