- Condition:New
- Certification:TUV, ISO, CE
- Material:Aluminum
- Light Way:Without Light
- Water Way:Outer Channel
- Usage Times:Non-Disposable
=== Base Info ===
- Model NO.:SEN-08C
- Application:Adult, Child
- Loading Way:Gland Type
- Head Diameter:Middle Head
- Exhaust Way:Exhaust Outside
- Number of Holes:Two Holes
- Connection:Without Quick Connector
- Rotating Speed:Low-Speed Handpiece
- Noise:Less Than 70dB
- Gear Rate:1:1
- Transport Package:Plastic Box
- Specification:Aluminum, stainless steel
- Trademark:TEALTH
- Origin:China
- HS Code:90184100
- Production Capacity:50000PCS,Year
=== Description ===
Basic Info.
Model NO.
SEN-08C
Application
Adult, Child
Loading Way
Gland Type
Head Diameter
Middle Head
Exhaust Way
Exhaust Outside
Number of Holes
Two Holes
Connection
Without Quick Connector
Rotating Speed
Low-Speed Handpiece
Noise
Less Than 70dB
Gear Rate
1:1
Transport Package
Plastic Box
Specification
Aluminum, stainless steel
Trademark
TEALTH
Origin
China
HS Code
90184100
Production Capacity
50000PCS/Year
Product Description
Product name: 20 degree straight dental handpiece
Order code: SEN-08C
Feature:
Precision design
Transmission gear is made of high strength alloy steel
Perfect Stable and reliable performance.
Adopted Imported Bearing,Smooth rotation, low noise, long life.
The international standard interface, universal.
Handpiece inserting & removal
Inserting
Insert the E-type handpiece onto the motor and turning all the way until it click to stop.
Removal
Grip both handpiece and motor respectively, pulling and separating.
dental handpiece
Turn the bur Lock Ring all the way in the direction of arrow marked "open" to open the chuck, remove out the bur.
Turn the bur Lock Ring all the way in the direction of arrow marked "open" to open the chuck, insert bur into chuck, return the bur Lock Ring in the direction of "close"until a click sound is heard.
Instruction:After each treatment,Sterilizing handpiece in autoclave according to the following steps:
1.Remove the bur and brush clean handpiece, clean outside of handpiece with an alcohol solution.
2.Lubricate handpiece, each times drop two drops inside of air inlet pipe.
3.Place into autoclaving pouch and mark.
4.Autoclave the handpiece for 12 min. at 135ºC.Operation Instruction:It shall be sterilized before handpiece is used at the first time;sterilization temperature is 135ºC and last for 12 minutes.
After using,Please follow the instruction to sterilize the handpiece:
1 extract the bur from the handpiece,use the soft brush to clean the dirt and wash with disinfection of alcohol cotton.
2 lubricate the handpiece,pour two drops into air tube one time.
3 wrap it with sterilization package and mark.
Please do not use the acid solution to scrub, inject or soak the handpiece.
Please do not autoclave the handpiece with residual chemical substances.
Handpiece should be packed well and place at clean and dry room without dust, sulfur and salt.
Please do not touch the handpiece immediately after autoclaving.