- Condition:New
- Certification:TUV, ISO, CE
- Material:Aluminum
- Light Way:Without Light
- Water Way:Outer Channel
- Usage Times:Non-Disposable
=== Base Info ===
- Model NO.:SEN-07C
- Application:Adult, Child
- Loading Way:Gland Type
- Head Diameter:Middle Head
- Exhaust Way:Exhaust Outside
- Number of Holes:Two Holes
- Connection:Without Quick Connector
- Rotating Speed:Low-Speed Handpiece
- Noise:Less Than 70dB
- Ratio:1:1
- Transport Package:Plastic Box
- Specification:Aluminum, stainless steel
- Trademark:TEALTH
- Origin:China
- HS Code:90184100
- Production Capacity:50000PCS,Year
=== Description ===
Basic Info.
Model NO.
SEN-07C
Application
Adult, Child
Loading Way
Gland Type
Head Diameter
Middle Head
Exhaust Way
Exhaust Outside
Number of Holes
Two Holes
Connection
Without Quick Connector
Rotating Speed
Low-Speed Handpiece
Noise
Less Than 70dB
Ratio
1:1
Transport Package
Plastic Box
Specification
Aluminum, stainless steel
Trademark
TEALTH
Origin
China
HS Code
90184100
Production Capacity
50000PCS/Year
Product Description
Name: External irrigation surgical Straight dental handpiece
Model : SEN-07CPacking List:
- Straight handpiece: 1 pcs
- Oil nozzle: 3 pcs
- English manual: 1 pcs
Features:
1.Ratio: E-type Low Speed Handpiece 1:1 Ratio, with external water Cooling System
3. Air Pressure: 245-392Kpa (2.5-4.0 kgf/cm²)
4. Water Pressure: 200Kpa (2kg)
5. Rotation Speed: 14,000-20,000 rpm
6. Bur Applicable: Φ2.334-2.355mm (CA BUR CONTRA ANGLE & HP BUR STRAIGHT CONE)
7. Noise: ≤65dBHandpiece inserting & removal
Inserting
Insert the E-type handpiece onto the motor and turning all the way until it click to stop.
Removal
Grip both handpiece and motor respectively, pulling and separating.
Forward/Reverse Rotation
1) Forward Rotation: Turn the FWD/REV change ring to "F".
2) Reverse Rotation: Turn the FWD/REV change ring to "R".
3) When the FWD/REV change ring is positioned in the middle of "F"and "R",the drive air is interrupted and the motor does not rotate.
4) When FEW/REV change ring is positioned in F or R, the rotation speed is maximum.
Maintenance & Care
After each treatment, sterilizing handpiece in autoclave according to the following steps:
1. Remove the bur, use brush to clean handpiece, then cleaning outside of handpiece with alcohol solution.
2. Lubricate handpiece.
3. Package into autoclaving pouch.
4. Autoclave the handpiece for 12 min at 135ºC.
5. Dental handpieces cannot be soaked in a disinfectant with acidic liquid. it will seriously damage the bearings and handpiece internal components
6. Do not use an ultrasonic cleaner to clean the dental handpiece.
7. It is not recommended to repair the dental handpiece by little experience person. For repairing, please return to the factory or send to the designated after-sales service maintenance office.