- Condition:New
- Certification:ISO, CE
- Material:Stainless Steel
- Light Way:With LED Light
- Water Way:Inner Channel
- Usage Times:Non-Disposable
=== Base Info ===
- Application:Adult, Child
- Loading Way:Gland Type
- Head Diameter:Middle Head
- Exhaust Way:Exhaust Outside
- Number of Holes:Non
- Connection:Without Quick Connector
- Rotating Speed:Low-Speed Handpiece
- Bur Applicable:Φ2.334-2.350mm
- Chuck Type:Push Button Type
- Transport Package:Standard Export Carton
- Specification:0.25kg
- Trademark:Topmed
- Origin:China
- HS Code:90184100
- Production Capacity:1000,Month
=== Description ===
Basic Info.
Application
Adult, Child
Loading Way
Gland Type
Head Diameter
Middle Head
Exhaust Way
Exhaust Outside
Number of Holes
Non
Connection
Without Quick Connector
Rotating Speed
Low-Speed Handpiece
Bur Applicable
Φ2.334-2.350mm
Chuck Type
Push Button Type
Transport Package
Standard Export Carton
Specification
0.25kg
Trademark
Topmed
Origin
China
HS Code
90184100
Production Capacity
1000/Month
Product Description
Product Description
TechnicalsBrand | Topmed |
Description | Fiber optic contra-angle handpiece 1:1 Ratio, with Internal Cooling System |
Air Pressure | 245-392Kpa(2.5-4.0 kgf/cm²) |
Water Pressure | 198Kpa (2kg) |
Rotation Speed | 22,000-27,000 rpm |
Chuck Type | Latch Type |
Bur Applicable | Φ2.334-2.355mm |
Noise | ≤70dB |
Source of light | haloid bulb |
Volt of bulb | 3.0-3.2V |
Features 1. Ratio:1:1
2. Working pressure:0.3-0.35MPa
3.Speed: 20,000rpm
4. Burs Applicable:2.35mm
5.Autoclaved:135ºC
6.The OEM is available
Picture
Handpiece maintaince
There are two methods of cleaning dental handpieces. One is to use an automatic handpiece system, such as the QUATTRO care Plus, prior to sterilization. The other option is to manually maintain your handpieces. If you elect to manually maintain your handpieces, here are the steps to do so.
Step 1: Clean Handpiece
The first step in cleaning a dental handpiece is to lightly wash the handpiece under cool running water to remove excess debris.
Step 2: Handpiece Lubrication
Following external cleaning, connect the handpiece to the handpiece lubricant spray using the appropriate nozzle for the handpiece you are cleaning. For this air handpiece, we are using a multiflex nozzle. Spray for approximately 2 seconds. We recommend using a cloth or paper towel wrapped around the handpiece to contain the spray. It is ok if some excess lubrication remains in the handpiece.
Step 3: Purge Handpiece
After lubrication, you'll want to purge your handpiece. Simply connect the handpiece to your multiflex connection, step on the foot petal and purge for 30-40 seconds. The handpiece is now ready for sterilization.About us