- Condition:New
- Certification:ISO, CE
- Material:Stainless Steel
- Light Way:Without Light
- Water Way:Outer Channel
- Usage Times:Non-Disposable
=== Base Info ===
- Model NO.:Low speed
- Application:Adult, Child
- Loading Way:Gland Type
- Head Diameter:Small Head
- Exhaust Way:Exhaust Outside
- Number of Holes:Non
- Connection:Without Quick Connector
- Rotating Speed:Low-Speed Handpiece
- Noise:Less Than 70dB
- Transport Package:Standard Export Carton
- Specification:100g,pcs
- Trademark:Topmed
- Origin:China
- HS Code:90184100
- Production Capacity:1000PCS,Month
=== Description ===
Model | Dental air motor |
Air pressure | 0.3mpa-0.35mpa |
Rotation speed | 200,000-300,000 rpm/min. |
Noise | lower than 70db |
Warranty | 12 months |
OEM | Availiable |
Features
Internal watercourse loe speed handpiece is a high performance air motor,speed 500~20000rmp, forward and reverse rotation.
Air motor helps to control the torque and speed precisely.generates powerful torque during slow speed rotation, easy for maintain and with long life.
135°C Autoclavable
Handpiece maintenance
Cleaning
There is many chippings left inside of the high speed handpiece during working, effact the speed. Wshing by special hanpiece cleanser after used.
Lubrication
Speed of handpiece in the working reaches 350000rpm, so Lubrication is necessary.In large working should be lubricate it once per day.
(Note: washing the handpiece by special cleanser please do not to touch the hose avoid the hose harding.)
Air pressure
Air pressure of handpiece between 2~3Mpa, the new hanpiece run-in-period the air pressure should be control in 2Mpa.
Needle and Handpiece
When the hand piece doesn't load needle, please don't let it idle, because it will damage the handpiece.
Handpiece maintaince
There are two methods of cleaning dental handpieces. One is to use an automatic handpiece system, such as the QUATTRO care Plus, prior to sterilization. The other option is to manually maintain your handpieces. If you elect to manually maintain your handpieces, here are the steps to do so.
Step 1: Clean Handpiece
The first step in cleaning a dental handpiece is to lightly wash the handpiece under cool running water to remove excess debris.
Step 2: Handpiece Lubrication
Following external cleaning, connect the handpiece to the handpiece lubricant spray using the appropriate nozzle for the handpiece you are cleaning. For this air handpiece, we are using a multiflex nozzle. Spray for approximately 2 seconds. We recommend using a cloth or paper towel wrapped around the handpiece to contain the spray. It is ok if some excess lubrication remains in the handpiece.
Step 3: Purge Handpiece
After lubrication, you'll want to purge your handpiece. Simply connect the handpiece to your multiflex connection, step on the foot petal and purge for 30-40 seconds. The handpiece is now ready for sterilization.Picture