Dental Supply 1: 1 Wrench Type Contra Angle Low Speed Handpiece
Guangdong Changxing Printing Service Co., Ltd. / 2022-06-09
- Condition:New
- Certification:ISO, CE
- Material:Stainless Steel
- Light Way:Without Light
- Water Way:Inner Channel
- Usage Times:Non-Disposable
=== Base Info ===
- Model NO.:Low speed handpiece
- Application:Adult, Child
- Loading Way:Wrench Type
- Head Diameter:Middle Head
- Exhaust Way:Exhaust Outside
- Number of Holes:Non
- Connection:Without Quick Connector
- Rotating Speed:Low-Speed Handpiece
- Noise:Less Than 70dB
- Reduction Contra Angle:1:1
- Compatible with:NSK Ex Nac-E
- Working Pressure:0.3-0.35MPa
- Speed:18000rpm
- Burs Applicable:2.35mm
- Autoclaved:135ºC
- OEM:Available
- Transport Package:Standard Export Carton
- Specification:0.10kg
- Trademark:Topmed
- Origin:China
- HS Code:90184100
- Production Capacity:1000,Month
=== Description ===
Type | Contra Angle Handpiece |
Chuck type | Wrench |
Ratio | 1:1 |
Air pressure | 0.25-0.3Mpa |
Max Speed | 22,000-27,000 rpm |
Burs applicable | φ2.35mm |
Noise | ≤70dB |
Features 1. Precise technology, Steady, no vibration while revolving, offering a steady operation.
2. Exquisite appearance, Modern clipper-built designation, with elegant and attractive appearance.
3. Durable and autoclavable
4. Fastidiously request for designation, technology and materials.
5. Easy to assemble intended for dental clinical treatment and prevention slow speed dental handpiece.
6. Suitable for any E-type headpiece accords with ISO standard low speed nsk handpiecePicture
Handpiece maintaince
There are two methods of cleaning dental handpieces. One is to use an automatic handpiece system, such as the QUATTRO care Plus, prior to sterilization. The other option is to manually maintain your handpieces. If you elect to manually maintain your handpieces, here are the steps to do so.
Step 1: Clean Handpiece
The first step in cleaning a dental handpiece is to lightly wash the handpiece under cool running water to remove excess debris.
Step 2: Handpiece Lubrication
Following external cleaning, connect the handpiece to the handpiece lubricant spray using the appropriate nozzle for the handpiece you are cleaning. For this air handpiece, we are using a multiflex nozzle. Spray for approximately 2 seconds. We recommend using a cloth or paper towel wrapped around the handpiece to contain the spray. It is ok if some excess lubrication remains in the handpiece.
Step 3: Purge Handpiece
After lubrication, you'll want to purge your handpiece. Simply connect the handpiece to your multiflex connection, step on the foot petal and purge for 30-40 seconds. The handpiece is now ready for sterilization.About us