Product Description
P7 Sagittal sawApplication:
For application in cutting bone during joint surgery.
With the perfect shape of ergonomic design, whole unit is autoclavable, motor is imported, low noise, steadily and quickly cutting, no damage for soft tissue, long service life. A variety of different thickness or the length of the saw blade for your selection .Common length are 70mm and 90mm, common thickness are 0.8mm and 1.0mm,saw blade also can be customized according to your request.Specification:Output power | 250W |
Speed(r.p.m) | / |
Oscillations (osc/min) | 0-15000 |
Torque(Nm) | / |
Operation(V) voltage | 12V |
Sterilization | 155°C |
Swings (°) | / |
Noise(db) | ≤75 |
Standard Configuration:
1. Handpiece*1
2. Battery*2- Battery case*2
3. Charger*1
4. Saw blade*3 (90mm*22mm*1.0mm/90mm*14mm*1.0mm/70mm*24mm*0.8mm)
5.Aseptic transfer kit*1
Features:P7 is a series of dedicated handpieces which provide the surgeon with power for the most demanding acetabular reaming procedures. POWER AND RELIABILITYHigh torque single function power tools. This has been achieved through continual engineering refinements.Advantages:
1.Our whole power tool can be autoclavable.
2.We can autoclavable for 135 °C (Improved type ≤ 155 °C ),with 1.6Mpa,in this way the bacilli and virus which can not killed by the suffocating will be killed.
3.We use environment friendly nickel-metal hydride battery.
4.The machine has very low noise.Notes:
1.Sterilize temperature ≤ 135 °C (Improved type ≤ 155 °C ),if the temperature is over 135 ° C ,the motor will be damaged.
2. The battery need to be get out of the power tool after surgery. Otherwise the small automatic discharge of the electric will make the life of the battery short.
4. The battery cannot be sterilized, it is not autoclavable.
5. The cranial bur must be washed right after the surgery by purger in order to avoid the blood stick in the bur, then we should make it dry.
6. The battery space in the handpiece of the tool should not have any water, after sterilization.
7.The cranial bur blade is made of medical stainless steel, in order to avoid broken, so it is flexible and not very hard, it is easy to be attrite, we suggest each blade only use for 1 surgery.