Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor

Laizhou Dechen Machinery Co., Ltd. / 2022-06-09

Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor

  • Teeth Whitening Method:Laser Whitening
  • Applicable Departments:Orthodontic Department
  • Certification:ISO, CE
  • Type:Cleaning & Filling Teeth Equipments
  • Material:Steel
  • Name:Dental Wireless Endo Motor

=== Base Info ===

  • Model NO.:SD-E07
  • Adaptor:AC100-240V, 50-60Hz
  • Battery:3.7V,900mAh
  • Net Weight:140g
  • Relative Humidity:10~80%Rh
  • Environment Temperature:0~40°c
  • Atmosphere Pressure:60kpa~106kpa
  • Color:White
  • Output Voltage:5V
  • Input Voltage:1A
  • Modle:9 Different Programs
  • Transport Package:Standard Exported Carton
  • Specification:ISO,CE
  • Trademark:Stardent
  • Origin:China
  • HS Code:90184990
  • Production Capacity:10000,Month

=== Description ===
1Battery Voltage3.7Vdc2Battery Capacity900mAh3Net Weight140g4Rated input voltageAC100~240V 50/60Hz5Output voltage5V6Input voltage

 1A


Features:
1. This unit can be used in independent endodontic shaping
2. 9 different programs can be preset according to requirement of operator.
3. When rotary file reaches preset torque, the file will automatically withdraw until   removal of resistance.
4. This unit is powered by rechargeable Lithium battery, in order to expand life span of   battery. The unit will be turned off automatically in 8 minutes without any uses.
5. Contra angle, file clip and lip hook can be 135ºC autoclaved.

Packing list:
1. Charger Base     ---1pc
2. Contra angle      ---1pc
3. Main Unit    ---1pc
4. AC Adapter       ---1pc
5. LED light        ---2pcs
6. User manual      ---1pc


Precautions
• The appliance must only be used with the manufacturer's original accessories.
• Never use any other AC adapters.
• The RPM number indicates true instrument speed when the appropriate reduction rate is selected. Make sure the selected reduction matches the ratio of the contra angle handpiece.
• If the motor stops or runs too fast, discontinue use and call for assistance.
• After sterilization, make sure the motor has reached a temperature below 40ºC before use.
• Do not introduce any oil into the micro motor.
• The system functions normally in the environment where the temperature is at 5-40ºC (50-104ºF), humidity at 10-85%RH, atmospheric pressure at 50-106KPa, and no moisture condensation in the Control Unit. Any use outside these limits may cause malfunction.
• Do not use a bent, damaged, deformed or non-ISO-conforming file. Using such a file may result in personal injury due to its unexpected breaking or "flying off" during rotation.
• Check the product before use by rotating it, paying attention to looseness, vibration, noise and temperature (heat generation). If any abnormal condition is found even slightly at that time, immediately stop use and contact your dealer.
• Always clean the shank of the file to be installed. Allowing dirt to enter the chuck could cause loss of concentricity and deterioration of chucking force.
• Before changing head or bur, turn off the power of the motor handpiece. Changing with the power kept on may cause unintended rotation by accidental touch of the ON/OFF button.
• Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrousoxide.

Notice
• Exercise sufficient care in using the product by giving patient safety first priority.
• Fully-charged rechargeable battery generally discharge gradually over time even the motor handpiece is not used. It is recommended to recharge the battery just before use.
• When the motor handpiece stops automatically by detecting a low battery voltage, turning on the power again after a while may not detect the low voltage immediately. This is not a failure, but due to battery characteristics. Since the voltage drop does not coincide with the remaining battery capacity, consider it only as a yardstick.
• When discarding the contra angle head and motor handpiece, dispose of them as medical waste.
• Users are responsible for operational control, maintenance and inspection.
• Store the system in place where temperature is at -10-50ºC (14-122ºF), humidity at 10-85%RH, atmospheric pressure at 50-106Kpa, and the system is not subject to air with dust, sulfur or salinity.

Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor
Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor
Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor
Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor
Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor
Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor
Payment:

1. Full payment should be made within 5 working days of placing your order.
2. After deliver goods, we will send the tracking number to you.
3. We accept Paypal, Western union and bank transfer.
4. Please make sure your payment address is correct.
5. Our price is EXW.


Our main products are dental unit,dental files,dental burs,dental handpiece,dental material,air compressor,autoclave,X ray unit,ultrasonic scaler,light cure,air turbine handpiece,intra-oral camera and apex locator.Meanwhile we can supply branded products from Dentsply,Saeshin,Saeyang,NSK,Woodpecker,Vita,Meta,Coxo,Greatstar,BEING,SINOL,RUNYES,GAPADENT, SUPLINE,SMIC and so on.
Stardent Equipment Co.,Limited is located in Foshan,Famous Town of Chinese Gongfu,central area of China, a traditional commerce city with rich history and culture. 
"For your better clinic,for all better teeth,for most beautiful smile" is our goal of developing.Welcome to visit website or company to know more.Thanks very much.
Any questions, please contact Sophie.



Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor
Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor

Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor
Dental Lab Equipment Root Canal Treatment LED Wireless Endo Motor
 

Copyright 2024 357th.com All Rights Reserved