Max.operating pressure | Port A,B,P | bar | 350 |
Port T | bar | 210 when the operating pressure exceed the permission value, port T must be be used as a draun port for spool symbol A and B |
Max flow-rate | L/min | 80 |
Flow cross section (switching neutral position) | Type Q | mm² | for symbol Q 6% of nominal cross section |
Type W | mm² | for symbol W 3% of nominal cross section |
Fluid | Mineral oil suitable for NBR and FKM seal |
Phosphate ester for FKM seal |
Fluid temperature range | ºC | -30 to +80 (NBR seal) |
-15 to +80(FKM seal) |
Viscosity range | mm²/s | 2.8 to 500 |
Degree of contamination | Maximum permissible degree of fluid contamination: 20/18/15, ISO 4406 |
Voltage type | DC | AC(rectifier) |
Usable voltage | 24 | 220 |
Allowed voltage (deviation) | % | ±10 |
Power consumption | W | 30 | - |
Holding power | VA | - | 50 |
Making capacity | VA | - | 220 |
Duty | 100% | 100% |
Switching time to ISO 6403 | ON | ms | 25 to 45 | 10 to 20 |
OFF | ms | 10 to 25 | 15 to 40 |
Switching frequency | Time/h | 15000 | 7200 |
Type of protection to DIN 40050 | IP65 | IP65 |