Rexroth A2fe80/90/160/180 Hydraulic Piston Motor for Construction
Wuxi Xu Cheng Packing Industry Co., Ltd. / 2022-06-27
- Certification:CE, ISO9001
- Excitation Mode:Other
- Power Rating:Adjustable
- Casing Protection:Iron Casting
- Number of Poles:Other
- Speed:High Speed
=== Base Info ===
- Model NO.:A2fe80,90,160,180
- Type:Plunger Type
- Model:A2fe
- Original:China
- Application:Construction Machinery
- Transport Package:Wooden Case for Export
- Specification:piston
- Trademark:FOCOR
- Origin:China
- HS Code:84122910
- Production Capacity:2000 Sets,Month
=== Description ===
Torque at Vg
Dp = 350 bar | T | 501 | 594 | 696 | 893 | 1003 | 1393 | 1978 | Dp = 400 bar | T | 573 | 679 | 796 | 1021 | 1146 | - | - |
Rotary stiffness | c | kNm/rad | 9.14 | 11.2 | 11.9 | 17.4 | 18.2 | 73.1 | 96.1 |
Moment of inertia | JGR | kgm2 | 0.0072 | 0.0116 | 0.0116 | 0.022 | 0.022 | 0.061 | 0.102 |
Maximum angular | a | rad/s2 | 6000 | 4500 | 4500 | 3500 | 3500 | 10000 | 8300 |
Case volume | V | L | 0.55 | 0.8 | 0.8 | 1.1 | 1.1 | 2.5 | 3.5 |
Mass (approx.) | m | kg | 25 | 34 | 36 | 47 | 48 | 82 | 110 |
Hydraulic fluidBefore starting project planning, please refer to our data sheets RE 90220 (mineral oil), RE 90221 (environmentally acceptable hydraulic fluids) and RE 90222 (HFD hydraulic fluids) and RE 90223 (HFA, HFB, HFC hydraulic fluids) for detailed information regarding the choice of hydraulic fluid and application conditions. The plug-in motor A2FE is not suitable for operation with HFA hydraulic fluid. If HFB, HFC or HFD or environmentally acceptable hydraulic fluids are used, the limitations regarding technical data or other seals must be observed.Details regarding the choice of hydraulic fluidThe correct choice of hydraulic fluid requires knowledge of the operating temperature in relation to the ambient temperature: in a closed circuit, the circuit temperature, in an open circuit, the reservoir temperature. The hydraulic fluid should be chosen so that the operating viscosity in the operating temperature range is within the optimum range (νopt), see shaded area of the selection diagram. We recommended that the higher viscosity class be selected in each case. Example: At an ambient temperature of X °C, an operating temperature of 60 °C is set in the circuit. In the optimum operating viscosity range (νopt., shaded area) this corresponds to the viscosity classes VG 46 or VG 68; to be selected: VG 68.Note: The case drain temperature, which is affected by pressure and speed, can be higher than the circuit temperature or reservoir temperature. At no point of the component may the temperature be higher than 115 °C. The temperature difference specified below is to be taken into account when determining the viscosity in the bearing. If the above conditions cannot be maintained due to extreme operating parameters, we recommend the use of a flushing and boost pressure valve.Shaft sealPermissible pressure loading the service life of the shaft seal is influenced by the speed of the axial piston unit and the case drain pressure (case pressure). The mean differential pressure of 2 bar between the case and the ambient pressure may not be enduringly exceeded at normal operating temperature. For a higher differential pressure at reduced speed, see diagram. Momentary pressure spikes (t < 0.1 s) of up to 10 bar are permitted. The service life of the shaft seal decreases with an increase in the frequency of pressure spikes.