120L CBEA 3:1 pilot ratio, standard capacity counterbalance valve

Suzhou Best Link New Material Co., Ltd. / 2022-06-27

120L CBEA 3:1 pilot ratio, standard capacity counterbalance valve

  • Function:Balance
  • Installation:Threaded Cartridge
  • Drive:Hydraulic
  • Type:Pilot-Operated Type
  • Pressure:280bar
  • Flow:120L,min

=== Base Info ===

  • Model NO.:CBEA
  • Cavity:T-2A
  • Pilot Ratio:3:1
  • Factory Pressure Settings Established at:2 in3;,min
  • Maximum Valve Leakage at Reseat:5 drops,min
  • Adjustment - No. of CCW Turns from Min.:3.75
  • Fluid:Mineral Oil or Phospate Ester
  • Temperature Rang:-30-120 Celsius Degree
  • Protection to DIN:IP65
  • Certificate:ISO9001
  • Transportation:Ocean,Land,Air,Express
  • Transport Package:Cartons and Pallets
  • Specification:T-2A
  • Trademark:Longli
  • Origin:China
  • HS Code:8412291000
  • Production Capacity:5000PCS,Year

=== Description ===

Basic Info.

Model NO. CBEA Cavity T-2A Pilot Ratio 3:1 Factory Pressure Settings Established at 2 in3;/min Maximum Valve Leakage at Reseat 5 drops/min Adjustment - No. of CCW Turns from Min. 3.75 Fluid Mineral Oil or Phospate Ester Temperature Rang -30-120 Celsius Degree Protection to DIN IP65 Certificate ISO9001 Transportation Ocean,Land,Air,Express Transport Package Cartons and Pallets Specification T-2A Trademark Longli Origin China HS Code 8412291000 Production Capacity 5000PCS/Year

Product Description

DESCRIPTION & OPERATION
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio.

Other names for this valve include motion control valve and over-center valve.

FEATURES

  • Counterbalance valves should be set at least 1.3 times the maximum load induced pressure.
  • Turn adjustment clockwise to decrease setting and release load.
  • Full clockwise setting is less than 200 psi (14 bar).
  • Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure.
  • Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit.
  • Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
  • This valve does not have positive seals on the pilot section and will pass up to 2 in³/min.@1000 psi (32 cc/min.@70 bar ) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies.
  • All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
 
CavityT-2A
Series2
Capacity120L
Pilot Ratio3:1
Maximum Recommended Load Pressure at Maximum Setting280bar
Maximum Setting350bar
Factory Pressure Settings Established at2 in³/min.
Maximum Valve Leakage at Reseat5 drops/min.
Adjustment - No. of CCW Turns from Min. to Max. Setting3.75
Operating CharacteristicStandard
Reseat>85% of setting
Model Weight0.3kg

120L CBEA 3:1 pilot ratio, standard capacity counterbalance valve
120L CBEA 3:1 pilot ratio, standard capacity counterbalance valve

120L CBEA 3:1 pilot ratio, standard capacity counterbalance valve

120L CBEA 3:1 pilot ratio, standard capacity counterbalance valve
Why Choose Us
1. With 30 years experience of hydraulic components in china.
2. Best manufacturing machinery, quality level, best price, best service.
3. We have very good and comprehensive after-sales service.
4. We have no MOQ for clients and tailor0made to clients request for our huge inventory.

Our Service
Pre-sale service: we provide presales in our first cooperation make clear your situation and give you some advice.
In-sale Service: We will track the production progress and quality, check the exact model and quantity one by one before delivering.
After-sale Service: We will provide a one year free warranty and lifetime maintenance. We will change all questions in 7*24hours if you buy from us.

Packing
Eternal Brand, Neutral or Customer's requires label. 
Neutral carton or same as the Customer's requires, export standard carton.
All cartons should be packed into the pallets more carefully.
All of the productions are inspected carefully one by one by QC before delivery.

Payment term:
T/T 50% as deposit in advance, the balance should be paid before delivery.100% L/C is acceptable. Western Union and PayPal is acceptable.
Transportation: By sea; By air; By truck; By express (DHL,TNT,UPS,FEDEX)
Trading term: FOB,CFR,CIF

120L CBEA 3:1 pilot ratio, standard capacity counterbalance valve
 

Copyright 2024 357th.com All Rights Reserved